GS230-HFC-4000-SE

SAMON REFRIGERANT GAS DETECTOR
VOLTAGE: 230VAC
GS230-HFC-4000-SE SAMON REFRIGERANT GAS DETECTOR
Catalog number 743030002
Manufacturer number 37-425-SE
Country of origin SE
HS number 85318070
  • Delivery stock products within 1-2 working days
  • Free delivery Netherlands > € 350,00 net
  • High stock level compressor spare parts
  • Only registered THIMAR customers
Product information "GS230-HFC-4000-SE"
G-Series gas detectors are field-proven over many years, offering simply reliable gas detection for commercial and industrial refrigerant applications.

There are a number of variants in the G-Series platform to meet application-specific needs, all sharing a common set of features.

These include:

- Operating status displayed via LEDs

- 3 x adjustable alarm levels

- 3 x alarm relay outputs

- Adjustable alarm delay

- Configurable alarm behaviour, auto-reset or latching

- Failsafe operation

- -40°C - + 50°C operating range suitable for all refrigeration environments

- Test terminal for service tools

- Annual maintenance using DT300 service tool

- Power supply options inc. 12-24V AC/DC & 230V AC

Our G-Series refrigerant gas detectors can be delivered with sensors for the following gas types:

CO2
HFC
HFO
NH3
R290
GD/GS/GSR/GR/GK:

Housing GS,GSR,GR,GK: Polycarbonate, (PC) IP54
Housing GD: Polycarbonate, (PC) IP21
Power supply: GD/GS/GSR/GR/GK-24: 12-24V AC/DC GD/GS/GSR/GR/GK-230: 230V AC, 50/60 Hz
Power consumption Max 2W
Indications: Power/Active and alarm indication on three levels.
Outputs relay: Potential free contacts (230V, max 5A) .
Ambient temp: "-40 °C - + 50 °C (Automatic temperature compensation)"
Humidity: 0-95% RH (non-condensing)
Glands: 4 of M16 membrane glands
Screw terminals: < 1,5 mm2, fuse < 10A
Accuracy: ± 5% of the measurement range
Sensor technology: Semi-conductive
Response time: 30 s
Sensors lifetime: 5 years
Max. Overrange: 130%
Applicable standards:
EN 378, EN 14624, JRA 4068

GSH/GSLS

Housing: Polycarbonate, PC, IP67
Power supply:
GSH230 / GSLS230 85230V AC, 50/60Hz
GSH24 / GSLS24 12..24V AC/DC
Power consumption: 3W
Indications: Power/Active and alarm indication on three levels
Outputs relay: Potential free contacts (230V, max 5A)
Ambient temp: -40 °C..+50 °C
Humidity: 0-95% Rh (non condensing)
Glands: < 1,5 mm2, fuse < 10A
GSMB:

Housing: Polycarbonate, PC, IP67
Power supply:
GSMB230 85..230V AC, 50/60Hz
GSMB24 12..24V AC/DC
Power consumption: 3W
Indications: Power/Active and alarm indication on three levels.
Outputs relay: Potential free contacts (230V, max 5A)
Ambient temp: 40°C..+50°C
Humidity: 0..95% RH (non-condensing)
Glands: 4 of M16 membrane glands
Screw terminals: < 2,5 mm2
Data format: Modbus RTU, 19200 baud, 8, N, 1.
Data output: RS-485 compatible ModBus RTU port. 3-pole screw terminal (A / B / GND) (8)
GXR

Housing: Polycarbonate, PC
Power supply: 230 V AC, 50/60 Hz (model Gx230-XX) - 12-24V AC/DC (model Gx24-XX)
Power consumption: Max 2W
Indications: Power/Active and alarm indication on three levels.
Outputs relay: Potential free contacts (230V, max 5A) .
Ambient temp: -40°C to +40°C (Automatic temperature compensation)
Humidity: 0-95% RH (non-condensing)
Glands: 4 of M16 membrane glands
Screw terminals: < 1,5 mm2, fuse < 10A
GD/GS/GSR/GR/GK:

Housing GS,GSR,GR,GK: Polycarbonate, (PC) IP54
Housing GD: Polycarbonate, (PC) IP21
Power supply: GD/GS/GSR/GR/GK-24: 12-24V AC/DC GD/GS/GSR/GR/GK-230: 230V AC, 50/60 Hz
Power consumption Max 2W
Indications: Power/Active and alarm indication on three levels.
Outputs relay: Potential free contacts (230V, max 5A) .
Ambient temp: "-40 °C - + 50 °C (Automatic temperature compensation)"
Humidity: 0-95% RH (non-condensing)
Glands: 4 of M16 membrane glands
Screw terminals: < 1,5 mm2, fuse < 10A
Accuracy: ± 5% of the measurement range
Sensor technology: Semi-conductive
Response time: 30 s
Sensors lifetime: 5 years
Max. Overrange: 130%
Applicable standards:
EN 378, EN 14624, JRA 4068

GSH/GSLS

Housing: Polycarbonate, PC, IP67
Power supply:
GSH230 / GSLS230 85230V AC, 50/60Hz
GSH24 / GSLS24 12..24V AC/DC
Power consumption: 3W
Indications: Power/Active and alarm indication on three levels
Outputs relay: Potential free contacts (230V, max 5A)
Ambient temp: -40 °C..+50 °C
Humidity: 0-95% Rh (non condensing)
Glands: < 1,5 mm2, fuse < 10A
GSMB:

Housing: Polycarbonate, PC, IP67
Power supply:
GSMB230 85..230V AC, 50/60Hz
GSMB24 12..24V AC/DC
Power consumption: 3W
Indications: Power/Active and alarm indication on three levels.
Outputs relay: Potential free contacts (230V, max 5A)
Ambient temp: 40°C..+50°C
Humidity: 0..95% RH (non-condensing)
Glands: 4 of M16 membrane glands
Screw terminals: < 2,5 mm2
Data format: Modbus RTU, 19200 baud, 8, N, 1.
Data output: RS-485 compatible ModBus RTU port. 3-pole screw terminal (A / B / GND) (8)
GXR

Housing: Polycarbonate, PC
Power supply: 230 V AC, 50/60 Hz (model Gx230-XX) - 12-24V AC/DC (model Gx24-XX)
Power consumption: Max 2W
Indications: Power/Active and alarm indication on three levels.
Outputs relay: Potential free contacts (230V, max 5A) .
Ambient temp: -40°C to +40°C (Automatic temperature compensation)
Humidity: 0-95% RH (non-condensing)
Glands: 4 of M16 membrane glands
Screw terminals: < 1,5 mm2, fuse < 10A